WaterMaster® Fire Hydrants

 Red WaterMaster 5CD350 fire hydrant assembly outside of storefront

Dry-barrel fire hydrants - available in 250 or 350 psi and backed with a 10 year limited warranty

La información se presenta en Inglés. Una vez traducida, está se actualizará.

EJ has been providing fire hydrants and other water distribution solutions to communities since the 1920s. Since that time, we've worked hard to maintain interchangeability so our new products can work with our old products.

Download the Water Distribution Solutions brochure

Ease of Maintenance

WaterMaster fire hydrant assemblies have some of the fewest parts (in unique parts and overall parts) in the industry means fewer parts to fail, keep on hand, remove during service, or cause confusion out in the field.

Made in the USA

All cast components are made and assembled in the United States of America.

New 350 psi Rated Hydrants

We are proud to offer new WaterMaster 350 fire hydrants in our CD and BR designs. All 350 psi rated fire hydrants are pressure tested to twice the rated working pressure (700 psi).


CD and BR Design Highlights

EJ primarily offers two styles of dry-barrel fire hydrants; CD and BR. Both designs operate nearly identical, with the most notable difference being the exterior "look" of the hydrant. EJ designs continue to evolve to meet the changing needs of water systems, which now include the option to have a 250 or 350 psi rated fire hydrant.

Learning from decades of experience with the BR design, the CD "Capital Dome" design incorporates ease of maintenance improvements while offering an alternative exterior look to a fire hydrant. The CD design is available as either a 5 1/4" or 4 1/2" hydrant.

CD Design Available Standard Nozzle Configurations

WaterMaster 5 1/4" CD fire hydrant design with 3-way configuration
5 1/4"
3-way (1 pumper / 2 hose)
WaterMaster 5 1/4" CD fire hydrant design with 2-way configuration
5 1/4"
2-way (2 pumper, 1 pumper / 1 hose, 2 hose)
WaterMaster 5 1/4" CD fire hydrant design with single pumper configuration
5 1/4"
Single (1 pumper)
WaterMaster 4 1/2" CD fire hydrant design with 3-way configuration
4 1/2"
3-way (1 pumper / 2 hose)
WaterMaster 4 1/2" CD fire hydrant design with 2-way configuration
4 1/2"
2-way (2 pumper, 1 pumper / 1 hose, 2 hose)

The BR hydrant was initially adopted as the Midwest standard for dry-barrel fire hydrants. The name was derived from the "breakable flanges," which are now referred to as "swivel flanges."

BR Design Available Standard Nozzle Configurations

WaterMaster 5 1/4" BR fire hydrant design with 3-way configuration
5 1/4"
3-way (1 pumper / 2 hose)
WaterMaster 5 1/4" BR fire hydrant design 2-way configuration
5 1/4"
2-way (2 pumper, 1 pumper / 1 hose, 2 hose)
WaterMaster 5 1/4" BR fire hydrant design with 3-way-configuration and snow barrel
5 1/4"
3-way (1 pumper / 2 hose)
Shown with snow barrel

Learning from decades of experience with the BR design, the CD "Capital Dome" design incorporates ease of maintenance improvements while offering an alternative exterior look to a fire hydrant. The CD design is available as either a 5 1/4" or 4 1/2" hydrant.

CD Design Available Standard Nozzle Configurations

WaterMaster 5 1/4" CD fire hydrant design with 3-way configuration
5 1/4"
3-way (1 pumper / 2 hose)
WaterMaster 5 1/4" CD fire hydrant design with 2-way configuration
5 1/4"
2-way (2 pumper, 1 pumper / 1 hose, 2 hose)
WaterMaster 5 1/4" CD fire hydrant design with single pumper configuration
5 1/4"
Single (1 pumper)
WaterMaster 4 1/2" CD fire hydrant design with 3-way configuration
4 1/2"
3-way (1 pumper / 2 hose)
WaterMaster 4 1/2" CD fire hydrant design with 2-way configuration
4 1/2"
2-way (2 pumper, 1 pumper / 1 hose, 2 hose)

The BR hydrant was initially adopted as the Midwest standard for dry-barrel fire hydrants. The name was derived from the "breakable flanges," which are now referred to as "swivel flanges."

BR Design Available Standard Nozzle Configurations

WaterMaster 5 1/4" BR fire hydrant design with 3-way configuration
5 1/4"
3-way (1 pumper / 2 hose)
WaterMaster 5 1/4" BR fire hydrant design 2-way configuration
5 1/4"
2-way (2 pumper, 1 pumper / 1 hose, 2 hose)
WaterMaster 5 1/4" BR fire hydrant design with 3-way-configuration and snow barrel
5 1/4"
3-way (1 pumper / 2 hose)
Shown with snow barrel

Red WaterMaster 5BR250 fire hydrant bonnet close up with EJ logo

Standard Features

  • Pressure rated for 250 or 350 psi
  • Ductile iron body
  • All bolts below grade are 304 stainless steel
  • Meets or exceeds the requirements of ANSI/AWWA C502, UL 246, Factory Mutual 1510, and NSF/ANSI 61 & 372.*
  • 10 year limited warranty
  • Made in the USA

*Contact your EJ Sales Representative for material certifications.

Options

  • CD or BR design
  • 3-way, 2-way, or single nozzle configuration
  • Variable nozzle sizes (2 1/2" – 5")
  • 5 1/4" or 4 1/2" valve opening
  • Operating nut (standard pentagon and square sizes, with custom options)
  • Direction of opening (right or left)
  • Depth of bury (2' 6" – 10')
  • Color
  • Shoe connection (flanged, flanged with mechanical joint valve, mechanical joint, mechanical joint - bored out for sand casting, plain end with gland)
  • Domestic stainless steel bolts
  • Extension, conversion, breakaway, and flange kits available

Dry-Barrel Fire Hydrant Specifications

Each WaterMaster fire hydrant assembly is built to your local specifications and the following Word documents are available to guide you through the hydrant options. If you are unsure of your local specifications or would like help with the specification process, please contact us today.

Learn More

Talk to an expert at EJ to find out how the innovative solutions by EJ can work for your next project. Contact us today.

Envíenos un correo electrónico hoy
Solicite un almuerzo y aprenda